Ready to onboard?
Are you ready to join DistyParts and
grow your business?
| Category | |
| Manufacturer Name | |
| Altitude Rating | |
| Applications | |
| Approval Agency | |
| Communication Protocol | |
| Current | |
| Defense/Aero Certification | |
| Dual Fused | |
| Efficiency | |
| Fanless | |
| Features | |
| Height | |
| Industrial Certification | |
| Input Surge Protection | |
| Length | |
| MOPP | |
| MTBF | |
| Medical Certification | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power (Watts) | |
| SEMI F47 Compliance | |
| Standard Number | |
| Standby Power | |
| Type | |
| Voltage | |
| Warranty | |
| Width |
The Advanced Energy CoolX®1000 series CX10S-HHHDCB-P-A-DK00000 is a high-performance, fanless AC DC converter designed for demanding applications. This enclosed unit provides up to 880W of power with a 5V output at 3A, suitable for ITE (Commercial) and Medical equipment.
Key features include 93% efficiency, universal input, and a wide operating temperature range of -40°C to 85°C. The converter supports PMBus™ for monitoring and control, along with adjustable output, remote sense, and standby output capabilities. Its compact dimensions (259.5mm x 164mm x 40.6mm) and chassis mount design facilitate integration into various systems.
Compliance with standards such as IEC60601-1, IEC60950-1, and IEC62368-1, along with approvals from CSA, EN, IEC, and UL, ensures reliability and safety. The fanless design eliminates acoustic noise and vibrations, making it ideal for sensitive environments. It also boasts high reliability with an MTBF of over 2,900,000 hours and a five-year warranty.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The power output is 880W.
The output voltage is 5V and the current rating is 3A.
The operating temperature range is -40°C to 85°C.
Yes, it supports PMBus™ for monitoring and control.
It is certified to IEC60601-1, IEC60601-1-2 (EMC), IEC60950, and IEC62368-1, with approvals from CSA, EN, IEC, and UL.