The Advanced Energy CoolX1000 series CX10S-HCHH00-P-A-DK00000 is a fanless, intelligent 1000W modular power supply, with this specific configuration delivering 500W. Packaged in a compact U-channel design measuring 259.5 mm x 164 mm x 40.6 mm, it provides robust power without requiring fan or base plate cooling, making it ideal for noise-sensitive environments.
This AC DC converter boasts a 93% efficiency and offers a 24V output at 6A, with adjustable output capabilities. It supports Universal Input and features PMBus communication for monitoring and control, along with Remote Sense and Standby Output. The unit is certified to medical standards like IEC60601-1 and industrial standards including IEC62368-1 and SEMI F47.
Designed for applications in ITE (Commercial) and Medical fields, this converter is suitable for demanding environments. Its chassis mount design and operating temperature range of -40°C to 85°C ensure versatility. The power supply also features high-input surge protection up to 4 kV line to PE and a Mean Time Between Failures (MTBF) exceeding 2,900,000 hours.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
This specific configuration of the CoolX1000 series delivers 500W.
The converter provides a 24V output at 6A.
The efficiency is 93%.
The dimensions are 259.5mm x 164.0mm x 40.6mm.
The operating temperature range is -40°C to 85°C.
Yes, it features PMBus for monitoring and control.
It meets standards including IEC60601-1, IEC60950-1, and IEC62368-1.