The Advanced Energy CoolX1000 series CX10S-HCDGGC-P-A-DK00000 is a high-performance, fanless 940W AC DC converter designed for demanding applications. This enclosed unit provides a 24V output at 3A and features a universal input.
Key specifications include 93% efficiency, adjustable output, PMBus communication for monitoring and control, and remote sense capabilities. The converter is built to meet stringent standards, with certifications including IEC60601-1, IEC60950-1, and IEC62368-1, making it suitable for both ITE (Commercial) and Medical applications.
With a compact chassis mount design measuring 259.5mm x 164.0mm x 40.6mm, it offers flexibility in system integration. The operating temperature range is -40°C to 85°C, ensuring reliable performance in various environments. The power supply also boasts a high MTBF of over 2,900,000 hours and comes with a five-year warranty, highlighting its reliability.
This model is ideal for applications requiring stable power, advanced control features, and compliance with medical and industrial safety standards. Its fanless design eliminates acoustic noise and vibration, beneficial for sensitive equipment.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The CX10S-HCDGGC-P-A-DK00000 provides a 24V output at 3A.
This AC DC converter has a power rating of 940W.
Key features include adjustable output, PMBus communication, remote sense, standby output, and universal input.
The operating temperature range is -40°C to 85°C.
It is certified to IEC60601-1, IEC60950-1, and IEC62368-1 standards, with approval from CSA, EN, IEC, and UL.
It is suitable for ITE (Commercial) and Medical applications.
The Mean Time Between Failures (MTBF) is greater than 2,900,000 hours.