| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Dimensions | |
| Efficiency | |
| Features | |
| Height | |
| Length | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power | |
| Power (Watts) | |
| Standard Number | |
| Type | |
| Voltage | |
| Width |
The Advanced Energy CoolX1000 series CX10S-HBBDHA-P-A-DK00000 is a high-performance AC DC converter designed for demanding applications. This fanless unit delivers up to 1000W of power with 93% efficiency, operating silently without acoustic noise or vibrations.
Key electrical specifications include a 12V, 6A output, and it supports universal input. The converter offers advanced features such as adjustable output, PMBus monitoring and control, remote sense, and standby output, providing system designers with enhanced flexibility and performance monitoring capabilities. It is certified to multiple standards including IEC60601-1, IEC60950-1, and IEC62368-1, making it suitable for both ITE (Commercial) and Medical applications.
Mechanically, the CX10S-HBBDHA-P-A-DK00000 features a chassis mount design with dimensions of 259.5mm x 164.0mm x 40.6mm. It operates reliably within a wide temperature range of -40°C to 85°C. The unit boasts a high MTBF of over 2,900,000 hours and includes high-input surge protection for harsh environments.
This converter is ideal for applications requiring reliable, noise-free power, such as clinical diagnostic equipment, medical lasers, industrial machines, and telecommunications systems.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The power output is 865W, with a maximum of 1000W mentioned in the datasheet.
The product data lists a 12V output with 6A current. The datasheet indicates multiple outputs are available.
The operating temperature range is -40°C to 85°C.
Yes, it features analog and digital management including PMBus monitoring and control capability.
It meets IEC60601-1, IEC60601-1-2 (EMC), IEC60950, IEC62368-1, and MIL-STD-810G standards.
The Mean Time Between Failures (MTBF) is greater than 2,900,000 hours.