The Advanced Energy CoolX1000 series, including the CX10S-HB0BA0-P-A-DK00000, offers a fanless 1000W modular power supply solution. This U-channel design measures 259.5 mm x 164 mm x 40.6 mm and provides 100% natural convection cooling without requiring a base plate, eliminating acoustic noise and vibrations. It is suitable for scientific, medical, and other sensitive applications.
Key electrical specifications include a 12V output with a 15A current rating, 5 outputs, and 565W total power. The converter boasts 93% efficiency and features like adjustable output, PMBus™ monitoring and control, remote sense, standby output, and universal input. It operates within a temperature range of -40°C to 85°C.
Compliance and safety certifications include IEC60601-1, IEC60601-1-2 (EMC), IEC60950, IEC62368-1, CSA, EN, IEC, and UL. It also meets SEMI F47* standards and is safety approved for up to 5000m altitude. The unit is designed for chassis mounting and offers flexibility with field-configurable options and series/parallel output capabilities.
This power supply is ideal for applications requiring high reliability and low acoustic noise, such as clinical diagnostic equipment, medical lasers, industrial machines, and telecommunications.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The datasheet specifies a power output of 1000W for the CoolX1000 series, while the product data lists 565W for this specific model.
The dimensions are 259.5 mm x 164 mm x 40.6 mm.
The operating temperature range is -40°C to 85°C.
Yes, it features analog and digital management with PMBus™ monitoring and control capability.
It holds medical certifications like IEC60601-1 and IEC60601-1-2, industrial certifications like IEC60950 and IEC62368-1, and defense/aero certification MIL-STD-810G.
The Mean Time Between Failures (MTBF) is greater than 2,900,000 hours.
The RoHS status is RoHS3 Compliant.