| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Features | |
| Height | |
| Length | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power (Watts) | |
| Standard Number | |
| Type | |
| Voltage | |
| Width |
The CX10S-HB0ACG-P-A-DK00000 is a 705W modular AC/DC power converter belonging to the CoolX®1000 series by Advanced Energy. Designed for space-constrained environments, this unit measures 259.5 mm x 164.0 mm x 40.6 mm and utilizes a compact U-channel form factor. It provides seven independent output channels, including configurations for 5V, 12V, and 24V rails, eliminating the need for base plate cooling or internal fans.
The system achieves 93% efficiency and relies entirely on natural convection for thermal management, ensuring silent operation suitable for medical and sensitive industrial applications. Digital monitoring and control are handled via an integrated PMBus interface, allowing precise adjustment and remote sensing. Certified to IEC 60601-1 for medical use and IEC 62368-1 for industrial equipment, it offers robust protection against input surges up to 4 kV.
The module supports chassis or DIN-rail mounting and carries a five-year warranty with an estimated MTBF exceeding 2.9 million hours. Its field-configurable plug-and-play architecture simplifies integration into clinical diagnostics, test equipment, and automation systems requiring vibration-free power delivery.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The module delivers a maximum total output power of 705 watts across its seven channels.
No, it utilizes 100 percent natural convection cooling and does not require a fan or base plate.
The unit supports PMBus digital communication for performance monitoring and control.
It is certified to IEC 60601-1 third edition for medical applications and IEC 62368-1 for industrial use.
The mean time between failures exceeds 2.9 million hours under standard operating conditions.