| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Dimensions | |
| Efficiency | |
| Features | |
| Height | |
| Length | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power | |
| Power (Watts) | |
| Standard Number | |
| Type | |
| Voltage | |
| Width |
The Advanced Energy CoolX1000 series, including the CX10S-HA0HCH-P-A-DK00000, represents a fanless, intelligent 1000 W modular power supply. This U-channel design provides high power output without requiring fan or base plate cooling, making it ideal for applications sensitive to acoustic noise or vibration, such as scientific and medical equipment.
The CX10S-HA0HCH-P-A-DK00000 features a 1000W power rating with 93% efficiency and a 5V output. It is designed for chassis mounting and includes features like adjustable output, PMBus™ monitoring and control, remote sense, standby output, and universal input. The compact dimensions are 259.5 mm x 164 mm x 40.6 mm.
This power supply meets stringent certification and compliance standards, including IEC60601-1 3rd edition and IEC60601-1-2 4th edition (EMC) for medical applications, and IEC60950, IEC62368-1, and SEMI F47* for industrial use. It also holds MIL-STD-810G compliance for defense and aerospace applications. The operating temperature range is -40°C to 85°C, with safety approvals up to 5000 m altitude.
With a Mean Time Between Failures (MTBF) exceeding 2,900,000 hours, high-input surge protection up to 4 kV, and reverse energy protection, this power supply is built for reliability in harsh environments. It offers flexibility through analog and digital communications (PMBus™) for monitoring and control.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The power output is 1000 W.
The output voltage is 5V.
The operating temperature range is -40°C to 85°C.
The dimensions are 259.5 mm x 164 mm x 40.6 mm (10 in x 6.5 in x 1U).
It complies with IEC60601-1 3rd edition, IEC60601-1-2 4th edition (EMC), IEC60950, IEC62368-1, and SEMI F47*.
The MTBF is greater than 2,900,000 hours.