The Advanced Energy CX10S-HA0HCD-P-A-DK00000 is an enclosed AC/DC converter from the CoolX1000 series, delivering 705W of power. It operates with a 5V output voltage and a maximum current of 8.3A, achieving an efficiency of 93%. This model supports universal input and features PMBus communication, adjustable output, remote sense, and a standby output.
Designed for ITE (Commercial) and Medical applications, this converter meets several safety standards including IEC60601-1 3rd edition, IEC60601-1-2 4th edition (EMC), IEC60950-1, and IEC62368-1. It also complies with 2 MOPP and is dual fused.
The physical dimensions are 259.5mm in length, 164.0mm in width, and 40.6mm in height, with a chassis mount type. The operating temperature range is from -40°C to 85°C. The unit is fanless, providing silent operation and enhanced reliability with an MTBF greater than 2,900,000 hours. It includes high-input surge protection up to 4 kV line to PE and has a five-year warranty.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The power output is 705W.
The output voltage is 5V and the output current is 8.3A.
The efficiency is 93%.
The operating temperature range is -40°C to 85°C.
It uses a chassis mount type.
Yes, it features PMBus monitoring and control capability.
It complies with IEC60601-1 3rd edition, IEC60601-1-2 4th edition (EMC), IEC60950, and IEC62368-1.