The Advanced Energy CoolX1000 series CX10S-GAAA0H-P-A-DK00000 is a fanless, intelligent 1000W modular power supply, with this specific unit delivering 535W. It features a U-channel design measuring 259.5 mm x 164 mm x 40.6 mm, providing up to 1000W without fan or base plate cooling, eliminating acoustic noise.
This AC/DC converter operates with a 5V output at 6A, achieving 93% efficiency. It supports universal input and includes features such as adjustable output, PMBus™ monitoring and control, remote sense, standby output, and dual fused protection. The unit is designed for reliability with an MTBF of over 2,900,000 hours and high-input surge protection up to 4 kV.
Compliance includes IEC60601-1 3rd edition, IEC60601-1-2 4th edition (EMC), IEC60950, IEC62368-1, SEMI F47*, and MIL-STD-810G. It is approved by CSA, EN, IEC, and UL. The operating temperature range is -40°C to 85°C. Mounting is via chassis mount.
Typical applications include ITE (Commercial) and Medical equipment, such as clinical diagnostic equipment, medical lasers, dialysis equipment, radiological imaging, and clinical chemistry. It is also suitable for test and measurement, industrial machines, automation equipment, printing, and telecommunications.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The CX10S-GAAA0H-P-A-DK00000 provides a 5V output at 6A.
This AC/DC converter has a power rating of 535W.
The efficiency of this unit is 93%.
The operating temperature range is -40°C to 85°C.
It complies with IEC60601-1 3rd edition, IEC60601-1-2 4th edition (EMC), IEC60950, IEC62368-1, SEMI F47*, and MIL-STD-810G.
The Mean Time Between Failures (MTBF) is greater than 2,900,000 hours.