The Advanced Energy CoolX1000 series, specifically the CX10S-DHCCDA-P-A-DK00000 model, is a fanless, intelligent 1000W modular power supply. Packaged in a compact U-channel design measuring 259.5 mm x 164 mm x 40.6 mm, it provides full power without requiring fan or base plate cooling, making it suitable for noise-sensitive environments.
This AC DC converter offers a 1000W output with 93% efficiency and a universal input. It features a 24V output voltage at 4.17A current, with seven outputs in total. Key features include adjustable output, PMBus™ monitoring and control, remote sense, standby output, and high-input surge protection up to 4 kV line to PE.
The CX10S-DHCCDA-P-A-DK00000 is certified to medical standards like IEC60601-1 and IEC60601-1-2, as well as industrial standards such as IEC60950 and IEC62368-1. It also meets SEMI F47 and MIL-STD-810G requirements, making it suitable for harsh industrial, defense, and aerospace applications. The operating temperature range is -40°C to 85°C.
Designed for ITE (Commercial) and Medical applications, this power supply's fanless operation eliminates acoustic noise and vibrations. Its modular design allows for field configuration and series/parallel output options for higher voltages or currents. Mounting options include base, side, and DIN-Rail.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The power output is 1000W.
The output voltage is 24V and the output current is 4.17A.
The operating temperature range is -40°C to 85°C.
It meets IEC60601-1 3rd edition, IEC60601-1-2 4th edition (EMC), IEC60950, IEC62368-1, SEMI F47*, and MIL-STD-810G.
Yes, it features PMBus™ monitoring and control capability.
The MTBF is greater than 2,900,000 hours.
The efficiency is 93%.