The Advanced Energy CoolX1000 series, including the CX10S-DDBCBH-P-A-DK00000, offers a fanless, intelligent 1000W modular power supply solution. This enclosed converter operates with a 12V, 6A output and provides 1000W of power with 93% efficiency. Its compact dimensions are 259.5mm x 164.0mm x 40.6mm.
Key features include adjustable output, PMBus monitoring and control, remote sense, standby output, and universal input. It is designed for applications requiring high reliability and low acoustic noise, such as ITE (Commercial) and Medical equipment. The operating temperature range is -40°C to 85°C.
Compliance includes standards like IEC60601-1, IEC60950-1, and IEC62368-1, with approval agencies such as CSA, EN, IEC, and UL. The unit is designed for chassis mounting and offers high-input surge protection up to 4 kV line to PE.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The CX10S-DDBCBH-P-A-DK00000 has a 12V output voltage and a 6A output current.
This AC DC converter has a power rating of 1000W.
Key features include adjustable output, PMBus™ monitoring and control, remote sense, standby output, and universal input.
The operating temperature range is -40°C to 85°C.
It meets IEC60601-1 3rd edition, IEC60601-1-2 4th edition (EMC), IEC60950, IEC62368-1, and MIL-STD-810G.
The efficiency of this power supply is 93%.
The MTBF for the CoolX1000 series is greater than 2,900,000 hours.