The Advanced Energy CoolX1000 series CX10S-DBAGAB-P-A-DK00000 is a fanless, intelligent 1000W modular power supply designed for demanding applications. This specific configuration provides 890W of power with a 5V output and 21A current, featuring 93% efficiency.
Key features include adjustable output, PMBus monitoring and control, remote sense, standby output, and universal input. The unit is built for reliability with an MTBF greater than 2,900,000 hours and high-input surge protection up to 4 kV line to PE. It operates across a wide temperature range of -40°C to 85°C.
Packaged in a compact U-channel design measuring 259.5 mm x 164 mm x 40.6 mm, it is suitable for chassis mounting. The power supply meets stringent medical and industrial standards, including IEC60601-1, IEC60950-1, and IEC62368-1, making it ideal for ITE (Commercial) and Medical applications.
This model offers flexibility with 7 outputs and supports analog and digital communications via PMBus. Its fanless design eliminates acoustic noise and vibrations, beneficial for sensitive environments.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The power supply provides up to 1000W, with this specific configuration rated at 890W.
This model features a 5V output voltage capable of delivering up to 21A.
The converter boasts an efficiency of 93%.
It can operate in temperatures ranging from -40°C to 85°C.
The dimensions are 259.5 mm in length, 164 mm in width, and 40.6 mm in height.
Yes, it features PMBus for monitoring and control capabilities.
It complies with medical standards like IEC60601-1 and IEC60601-1-2 (EMC), and industrial standards such as IEC60950-1 and IEC62368-1.