| Width |
The Advanced Energy CX10S-DB0CCC-P-A-DK00000 is part of the CoolX1000 series, a fanless, intelligent modular power supply. This U-channel design delivers 980W of power with natural convection cooling, eliminating acoustic noise and vibrations.
Key electrical specifications include a 93% efficiency and a universal input. It offers five outputs, with a primary output voltage of 24V and a current of 8.3A. Features such as adjustable output, PMBus™ monitoring and control, remote sense, and standby output enhance its flexibility for various applications.
Mechanically, the unit measures 259.5mm x 164.0mm x 40.6mm and is designed for chassis mounting. It meets stringent safety standards including IEC60601-1, IEC60950-1, and IEC62368-1, making it suitable for ITE (Commercial) and Medical applications.
The power supply operates within a wide temperature range of -40°C to 85°C and boasts a high MTBF of over 2,900,000 hours, indicating excellent reliability. It also includes high-input surge protection up to 4 kV line to PE.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The maximum power output is 980W.
This model has 5 outputs.
The operating temperature range is -40°C to 85°C.
The dimensions are 259.5mm x 164.0mm x 40.6mm.
It complies with IEC60601-1, IEC60950-1, and IEC62368-1 standards.
Yes, it features fanless operation with natural convection cooling.
The MTBF is greater than 2,900,000 hours.