| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Features | |
| Height | |
| Length | |
| Medical Grade | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power (Watts) | |
| Standard Number | |
| Type | |
| Voltage | |
| Width |
The Advanced Energy CX10S-CGAD0D-P-A-DK00000 is an enclosed AC/DC converter from the CoolX1000 series, delivering 825W of power. This unit features 6 outputs, with a primary voltage of 24V and a current rating of 4.17A. It operates with high efficiency, rated at 93%, and supports a wide input voltage range.
Designed for versatility, this converter includes features such as adjustable output, remote sense, and PMBus™ digital communication for monitoring and control. Its operating temperature range is from -40°C to 85°C, making it suitable for demanding environments. The physical dimensions are 259.5mm in length, 164.0mm in width, and 40.6mm in height, with a chassis mount type.
Compliance is met with standards including IEC60601-1, IEC60950-1, and IEC62368-1, and it is approved by agencies such as CSA, EN, IEC, and UL. The converter is also RoHS3 compliant and has an MSL rating of 1.
Typical applications for this converter include ITE (Commercial) and Medical equipment, where reliable and flexible power conversion is essential. Its robust design and comprehensive features make it a suitable choice for various industrial and commercial systems.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The CX10S-CGAD0D-P-A-DK00000 provides 825W of power.
This converter has 6 outputs, including a 24V output with a current rating of 4.17A.
The efficiency of this AC/DC converter is 93%.
The operating temperature range is -40°C to 85°C.
The dimensions are 259.5mm in length, 164.0mm in width, and 40.6mm in height.
Yes, the CX10S-CGAD0D-P-A-DK00000 features PMBus™ for monitoring and control.
It meets IEC60601-1, IEC60950-1, and IEC62368-1 standards and is approved by CSA, EN, IEC, and UL.