| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Configuration | |
| Current | |
| Dimensions | |
| Efficiency | |
| Features | |
| Height | |
| Length | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power (Watts) | |
| Standard Number | |
| Type | |
| Voltage | |
| Width |
The Advanced Energy CoolX®1000 series, including the CX10S-CDDDBC-P-A-DK00000, offers a fanless, intelligent 1000W modular power supply solution. This U-channel design provides high power output without requiring fan or base plate cooling, making it suitable for applications sensitive to acoustic noise or vibration. The unit operates with 100% natural convection cooling and boasts 93% efficiency.
Key electrical specifications include a 1000W power output, a nominal 48V output voltage, and 8.3A current. It supports universal input and features adjustable output, PMBus™ monitoring and control, remote sense, and a standby output. The converter is designed for chassis mounting and has dimensions of 259.5 mm x 164 mm x 40.6 mm.
This power supply is certified for medical applications under IEC60601-1 and IEC60601-1-2, as well as industrial standards like IEC60950 and IEC62368-1. It also meets SEMI F47* and MIL-STD-810G requirements. Typical applications include ITE (Commercial) and Medical equipment.
Reliability is enhanced with an MTBF of over 2,900,000 hours, high-input surge protection up to 4 kV, and a five-year warranty. The operating temperature range is -40°C to 85°C.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The nominal output voltage is 48V.
The maximum output current is 8.3A.
The dimensions are 259.5 mm x 164 mm x 40.6 mm.
The operating temperature range is -40°C to 85°C.
It is certified under IEC60601-1, IEC60601-1-2, IEC60950, IEC62368-1, SEMI F47*, MIL-STD-810G, CSA, EN, IEC, and UL.
The MTBF is greater than 2,900,000 hours.
Yes, it features fanless operation with 100% natural convection cooling.