The Advanced Energy CoolX1000 series, including the CX10S-CDCDDG-P-A-DK00000, is a fanless, intelligent 1000W modular power supply. Packaged in a compact U-channel design measuring 259.5 mm x 164 mm x 40.6 mm, it provides 1000W without fan or base plate cooling, eliminating acoustic noise.
This AC/DC converter offers a 24V output voltage and 3A current, with a high efficiency of 93%. It operates across a wide temperature range of -40°C to 85°C. Key features include adjustable output, PMBus™ monitoring and control, remote sense, standby output, and universal input.
The CX10S-CDCDDG-P-A-DK00000 is designed for ITE (Commercial) and Medical applications. It meets standards such as IEC60601-1, IEC60950-1, and IEC62368-1, and is approved by agencies including CSA, EN, IEC, and UL. Its chassis mount design makes it suitable for integration into various systems.
Reliability is enhanced with an MTBF of over 2,900,000 hours and high-input surge protection up to 4 kV line to PE. The power supply also features reverse energy protection and safety approval for operation up to 5000m altitude.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The power output is 1000W.
The output voltage is 24V and the output current is 3A.
The operating temperature range is -40°C to 85°C.
The dimensions are 259.5mm in length, 164.0mm in width, and 40.6mm in height.
Yes, it features PMBus™ monitoring and control capability.
It complies with IEC60601-1, IEC60950-1, and IEC62368-1 standards.
The MTBF is greater than 2,900,000 hours.