The Advanced Energy CX10S-CABHG0-P-A-DK00000 is an enclosed AC/DC converter designed for ITE (Commercial) and Medical applications. It delivers up to 705W of power with a 12V output and 3A current, boasting an efficiency of 93%.
This model operates within a wide temperature range of -40°C to 85°C and supports universal input. Key features include adjustable output, PMBus™ monitoring and control, remote sense, standby output, and dual fused protection. The dimensions are 259.5mm x 164.0mm x 40.6mm, with chassis mount capability.
The CoolX1000 series, to which this part belongs, is known for its fanless design, providing 1000W with natural convection cooling. It meets various safety and compliance standards including IEC60601-1, IEC60950-1, and IEC62368-1, and is approved for use up to 5000m altitude.
This converter offers flexibility with field-configurable options and series/parallel output capabilities for higher voltages or currents. Its reliability is indicated by an MTBF of over 2,900,000 hours and high-input surge protection.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The CX10S-CABHG0-P-A-DK00000 provides 705W of power.
This converter has a 12V output voltage and a maximum current of 3A.
The operating temperature range is -40°C to 85°C.
Yes, it features PMBus™ monitoring and control capability.
The dimensions are 259.5mm in length, 164.0mm in width, and 40.6mm in height.
It meets IEC60601-1 3rd edition, IEC60601-1-2 4th edition (EMC), IEC60950, and IEC62368-1.
The MTBF is rated at over 2,900,000 hours.