Ready to onboard?
Are you ready to join DistyParts and
grow your business?
| Category | |
| Manufacturer Name | |
| Altitude Rating | |
| Applications | |
| Approval Agency | |
| Cooling | |
| Current | |
| Defense/Aero | |
| Dimensions | |
| Efficiency | |
| Features | |
| Height | |
| Industrial | |
| Input Surge Protection | |
| Length | |
| MTBF | |
| Medical | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power (Watts) | |
| Standard Number | |
| Standby Power | |
| Type | |
| Voltage | |
| Width |
The Advanced Energy CX10S-BHHCCA-P-A-DK00000 is a fanless, intelligent 1000W modular power supply from the Excelsys CoolX1000 series. This U-channel design provides up to 1000W without fan or base plate cooling, making it suitable for applications sensitive to acoustic noise or vibration.
Key electrical specifications include 885W of power, 93% efficiency, and a 24V output voltage with 8.3A current. It offers universal input and features like adjustable output, PMBus™ monitoring and control, remote sense, and a standby output. The operating temperature range is -40°C to 85°C.
Mechanically, the unit measures 259.5mm x 164mm x 40.6mm and is designed for chassis mounting. It carries multiple certifications including CSA, EN, IEC, and UL, and complies with standards such as IEC60601-1, IEC60950-1, and IEC62368-1. The power supply is also compliant with medical and industrial safety requirements.
Typical applications include ITE (Commercial) and Medical equipment. The high MTBF of over 2,900,000 hours and a five-year warranty underscore its reliability.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The power output is 885W.
The efficiency is 93%.
The output voltage is 24V and the output current is 8.3A.
The operating temperature range is -40°C to 85°C.
The dimensions are 259.5 mm x 164 mm x 40.6 mm.
Yes, it features PMBus™ for monitoring and control.
It complies with IEC60601-1, IEC60950-1, and IEC62368-1.