The Advanced Energy CoolX1000 series, including the CX10S-BHDA00-P-A-DK00000, represents a 1000W fanless modular power supply. This U-channel design measures 259.5 mm x 164 mm x 40.6 mm, providing high power output without the need for fan or base plate cooling. This eliminates acoustic noise and vibrations, making it suitable for sensitive scientific, medical, and industrial environments.
The CX10S-BHDA00-P-A-DK00000 features a 24V output voltage and a maximum current of 4.17A, delivering 585W of power. It boasts 93% efficiency and operates across a wide temperature range of -40°C to 85°C. The unit supports universal input and includes features like adjustable output, PMBus™ monitoring and control, remote sense, and standby output.
Compliance certifications include IEC60601-1, IEC60601-1-2 (EMC), IEC60950-1, IEC62368-1, SEMI F47, and MIL-STD-810G. It is also rated for 2 MOPP and has dual fused protection. The power supply is designed for ITE (Commercial) and Medical applications, offering flexibility with multiple outputs and mounting options.
Reliability is highlighted by an MTBF of over 2,900,000 hours and high-input surge protection up to 4 kV. The fanless design ensures quiet operation and reduced maintenance, making it a robust solution for demanding applications.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The Advanced Energy CX10S-BHDA00-P-A-DK00000 has a power output of 1000W.
This AC DC converter provides a 24V output voltage at 4.17A, delivering 585W.
The operating temperature range is -40°C to 85°C.
Yes, the CX1000 series, including this model, is fanless, utilizing natural convection cooling.
It meets IEC60601-1, IEC60601-1-2 (EMC), IEC60950-1, IEC62368-1, SEMI F47, and MIL-STD-810G.
The Mean Time Between Failures (MTBF) is greater than 2,900,000 hours.