| Width |
The Advanced Energy CoolX1000 series, specifically the CX10S-BGG0BB-P-A-DK00000 model, is a fanless, intelligent 1000W modular power supply. Packaged in a compact U-channel design measuring 259.5 mm x 164 mm x 40.6 mm, it provides high power output without requiring fan or base plate cooling, making it ideal for applications sensitive to acoustic noise or vibration.
This AC/DC converter features a 24V output with a 15A current rating and achieves an efficiency of 93%. It supports adjustable output, PMBus™ monitoring and control, remote sense, standby output, and universal input. The unit is certified to medical standards like IEC60601-1 and IEC60601-1-2, as well as industrial standards including IEC60950 and IEC62368-1, and defense/aero standards like MIL-STD-810G.
Designed for versatility, the CX10S-BGG0BB-P-A-DK00000 is suitable for ITE (Commercial) and Medical applications such as clinical diagnostic equipment, medical lasers, and radiological imaging. Its robust design includes high-input surge protection up to 4 kV line to PE and an operating temperature range of -40°C to 85°C. The power supply also boasts a high MTBF of over 2,900,000 hours and comes with a five-year warranty.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The Advanced Energy CX10S-BGG0BB-P-A-DK00000 provides 1000W of power.
This AC/DC converter has a 24V output voltage and a 15A output current.
The efficiency rating for this model is 93%.
The operating temperature range is -40°C to 85°C.
The dimensions are 259.5 mm x 164 mm x 40.6 mm.
It is certified to IEC60601-1, IEC60601-1-2 (EMC), IEC60950, IEC62368-1, MIL-STD-810G, and approved by CSA, EN, and UL.
The Mean Time Between Failures (MTBF) is greater than 2,900,000 hours.