The Advanced Energy CoolX®1000 series, specifically the CX10S-BADGCC-P-A-DK00000 model, is a fanless, intelligent 1000W modular power supply designed for demanding applications. It delivers up to 1000W of power with 100% natural convection cooling, eliminating acoustic noise and vibrations, making it suitable for scientific, medical, and industrial environments sensitive to noise or vibration.
This power supply boasts a high efficiency of 93% and features a 48V output with 8.3A current capability. It supports universal input and includes features like adjustable output, PMBus™ monitoring and control, remote sense, and standby output. The compact U-channel design measures 259.5 mm x 164 mm x 40.6 mm, facilitating chassis mounting.
Compliance is a key aspect, with certifications including IEC60601-1, IEC60601-1-2 (EMC), IEC60950-1, IEC62368-1, and SEMI F47*. It is also approved for operation at altitudes up to 5000m. The operating temperature range is -40°C to 85°C, and it has an MTBF of over 2,900,000 hours, ensuring high reliability for critical applications.
Typical applications include clinical diagnostic equipment, medical lasers, industrial machines, automation, and telecommunications. Its flexibility allows for field configuration and series/parallel output options for higher voltages or currents.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The power output is 1000W.
The output voltage is 48V and the output current is 8.3A.
The efficiency is 93%.
The operating temperature range is -40°C to 85°C.
Yes, it features fanless operation with natural convection cooling.
It meets IEC60601-1, IEC60601-1-2 (EMC), IEC60950-1, IEC62368-1, and SEMI F47* standards.