The Advanced Energy CoolX1000 series CX10S-BACDH0-P-A-DK00000 is a 1000W class, fanless modular power supply designed for high reliability and low acoustic noise. This specific model provides 785W of power with a 24V output at 3A, featuring six outputs and a universal input capability.
Designed for demanding applications, it operates within a wide temperature range of -40°C to 85°C and boasts 93% efficiency. Key features include adjustable output, PMBus™ monitoring and control, remote sense, and a standby output. Its compact dimensions of 259.5mm x 164mm x 40.6mm allow for chassis mounting.
Compliance with standards such as IEC60601-1, IEC60950-1, and IEC62368-1, along with approvals from CSA, EN, IEC, and UL, make it suitable for ITE (Commercial) and Medical applications. The fanless design eliminates acoustic noise and vibrations, making it ideal for sensitive environments. It also includes high-input surge protection up to 4 kV.
Reliability is further enhanced by a high MTBF rating of over 2,900,000 hours and safety approvals for operation up to 5000m altitude.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The power output is 785W.
The output voltage is 24V and the output current is 3A.
The operating temperature range is -40°C to 85°C.
The dimensions are 259.5mm in length, 164.0mm in width, and 40.6mm in height.
It complies with IEC60601-1, IEC60950-1, and IEC62368-1 standards.
No, this power supply features a fanless design for natural convection cooling.
The MTBF rating is greater than 2,900,000 hours.