The Advanced Energy CoolX1000 series CX10S-BAAD0A-P-A-DK00000 is a fanless, intelligent 1000W modular power supply, configured here to deliver 695W. This enclosed AC DC converter features a U-channel design with dimensions of 259.5 mm x 164 mm x 40.6 mm, suitable for chassis mounting.
Key electrical specifications include a 12V output voltage and 21A current capability, with a total power output of 695W. The unit boasts 93% efficiency and operates across a wide temperature range of -40°C to 85°C. It supports universal input and offers features such as adjustable output, PMBus monitoring and control, remote sense, standby output, and dual fused protection.
This power supply is designed for reliability, with an MTBF exceeding 2,900,000 hours and high-input surge protection up to 4 kV line to PE. It is safety approved for operation up to 5000m altitude and comes with a five-year warranty.
The CX10S-BAAD0A-P-A-DK00000 meets stringent compliance requirements, including IEC60601-1 3rd edition, IEC60601-1-2 4th edition (EMC) for medical applications, and IEC60950-1, IEC62368-1, and SEMI F47* for industrial use. It is also compliant with RoHS3 standards.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The CX10S-BAAD0A-P-A-DK00000 provides 695W of power.
The power supply has a 12V output voltage and a 21A current rating.
The operating temperature range is -40°C to 85°C.
Yes, it features PMBus for monitoring and control.
It meets IEC60601-1, IEC60601-1-2 (EMC), IEC60950-1, and IEC62368-1 standards.
The Mean Time Between Failures (MTBF) is greater than 2,900,000 hours.
The dimensions are 259.5mm x 164.0mm x 40.6mm.