| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Features | |
| Height | |
| Length | |
| Medical Grade | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Output Configuration | |
| Power (Watts) | |
| SVHC Present | |
| Standard Number | |
| Type | |
| Voltage | |
| Width |
The Advanced Energy CoolX®1000 series, specifically the CX10S-ADDABC-P-A-DK00000 model, is a 1000W (990W reported) fanless modular power supply designed for high reliability and low acoustic noise.
This enclosed unit features a chassis mount and measures 259.5mm x 164.0mm x 40.6mm. It provides up to 6 outputs, with a primary 48V output capable of 8.3A, and boasts 93% efficiency. Key electrical features include adjustable output, PMBus™ monitoring and control, remote sense, standby output, and universal input.
Designed for demanding environments, the CX10S series complies with medical standards like IEC60601-1 and IEC60601-1-2, as well as industrial standards such as IEC60950 and IEC62368-1. It also meets SEMI F47 requirements. The operating temperature range is -40°C to 85°C, and it is safety approved for altitudes up to 5000m.
With an MTBF exceeding 2,900,000 hours and high-input surge protection, this power supply is suitable for ITE (Commercial) and Medical applications where reliability and quiet operation are critical. Its fanless design eliminates acoustic noise and vibrations, making it ideal for sensitive scientific and medical equipment.
The output voltage is 48V and the output current is 8.3A.
Dimensions are 259.5mm x 164.0mm x 40.6mm (10.22 x 6.46 x 1.60 inches). Mounting options include chassis mount, base/side mount, and DIN-rail mounting.
The operating temperature range is -40°C to 85°C.
Medical certifications: IEC60601-1 3rd edition, IEC60601-1-2 4th edition (EMC), 2 MOPP, dual fused. Industrial certifications: IEC60950, IEC62368-1, SEMI F47. Defense/aerospace: MIL-STD-810G.
The efficiency is 93%.
Yes, it supports PMBus for monitoring and control, as well as analog management.
The MTBF is greater than 2,900,000 hours.