The Advanced Energy CoolX1000 series CX10S-ADCBBB-P-A-DK00000 is a fanless, intelligent 1000W modular power supply. Packaged in a compact U-channel design, it provides 1000W with natural convection cooling, eliminating acoustic noise and vibrations. This makes it suitable for scientific, medical, and other sensitive applications.
Key electrical specifications include a 1000W output power, a 24V output voltage at 15A, and 93% efficiency. It features 6 outputs and supports universal input. The converter includes features such as adjustable output, PMBus™ monitoring and control, remote sense, standby output, and high-input surge protection up to 4 kV line to PE.
With dimensions of 259.5 mm x 164 mm x 40.6 mm, it is designed for chassis mounting. The operating temperature range is -40°C to 85°C. The power supply is certified to medical standards like IEC60601-1 and IEC60601-1-2, as well as industrial standards like IEC60950 and IEC62368-1. It also meets SEMI F47* requirements.
This power supply is ideal for applications in ITE (Commercial) and Medical sectors, including clinical diagnostic equipment, medical lasers, and radiological imaging. Its robust design and compliance with various standards ensure reliability in demanding environments.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The power output is 1000W.
The main output voltage is 24V and the current is 15A.
The efficiency is 93%.
The operating temperature range is -40°C to 85°C.
The dimensions are 259.5mm in length, 164.0mm in width, and 40.6mm in height.
Yes, it features PMBus™ monitoring and control.
It complies with IEC60601-1, IEC60601-1-2 (EMC), IEC60950, and IEC62368-1.