| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Configuration | |
| Current | |
| Dimensions | |
| Efficiency | |
| Features | |
| Height | |
| Length | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Output Configuration | |
| Power | |
| Power (Watts) | |
| Standard Number | |
| Type | |
| Voltage | |
| Width |
The Advanced Energy CX10S-0HHABB-P-A-DK00000 is an enclosed AC/DC converter designed for ITE (Commercial) and Medical applications. This unit provides 665W of power across 7 outputs, with a primary 5V output capable of 15A.
Key electrical specifications include a high efficiency of 93% and a wide operating temperature range from -40°C to 85°C. The converter supports adjustable output, PMBus™ monitoring and control, remote sense, and a standby output. Its universal input capability enhances its flexibility in various system designs.
Mechanically, the unit features a chassis mount design with dimensions of 259.5mm x 164.0mm x 40.6mm. It meets several standard certifications including IEC60601-1, IEC60950-1, and IEC62368-1, along with approvals from CSA, EN, IEC, and UL.
The CoolX1000 series, to which this model belongs, is known for its fanless design, providing silent operation and reliability. This makes it suitable for applications sensitive to acoustic noise or vibration.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The unit operates reliably between -40°C and 85°C using fanless convection cooling.
It delivers seven independent regulated outputs configured for dual 12V, triple 5V, and dual 24V rails.
Yes, it features analog and digital management with full PMBus monitoring and control capability.
The 1U chassis supports base mounting, side mounting, and DIN-rail installation.
It holds IEC 60601-1 third edition certification with two MOPP ratings and dual fused protection.
The calculated mean time between failures exceeds 2,900,000 hours under standard conditions.