The Advanced Energy CoolX®1000 series, including the CX10S-0GGDHB-P-A-DK00000, is a fanless, intelligent 1000 W modular power supply. Packaged in a compact U-channel design measuring 259.5 mm x 164 mm x 40.6 mm, it provides high power output without requiring fan or base plate cooling. This design eliminates acoustic noise, making it suitable for scientific, medical, and vibration-sensitive applications.
The CoolX1000 series offers flexibility with analog and digital communications, including PMBus™ monitoring and control. It features 93% efficiency, an MTBF of over 2,900,000 hours, and high-input surge protection up to 4 kV line to PE. The power supply is safety approved for operation up to 5000 m altitude.
This enclosed, chassis mount AC/DC converter is designed for ITE (Commercial) and Medical applications. It supports adjustable output, remote sense, standby output, and universal input. Compliance includes IEC60601-1, IEC60601-1-2, IEC60950-1, IEC62368-1, SEMI F47, and MIL-STD-810G.
Key specifications include a 720W output power, 5V output voltage, and 6A current. The operating temperature range is -40°C to 85°C. It has 8 outputs and features like adjustable output, PMBus™, remote sense, standby output, and universal input.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The power output is 1000 W.
Key features include fanless cooling, PMBus™ monitoring and control, adjustable output, remote sense, standby output, and universal input.
The operating temperature range is -40°C to 85°C.
It meets IEC60601-1, IEC60601-1-2 (EMC), IEC60950-1, IEC62368-1, SEMI F47*, and MIL-STD-810G.
The efficiency is 93%.
The Mean Time Between Failures (MTBF) is greater than 2,900,000 hours.