| Turns Ratio |
The Coilcraft CST2-100LC is a wound primary current sense transformer with a peak primary current rating of 10 A. It offers a turns ratio of 1:100 and a secondary inductance of 2000 µH, with a load resistance of 10 ohm.
This transformer operates efficiently within a frequency range of 50 kHz to 1000 kHz and is designed for surface mounting. Its operating temperature range spans from -40 °C to 125 °C, making it suitable for various industrial applications.
The CST2-100LC is RoHS3 compliant and lead-free, indicating adherence to environmental standards. Its physical dimensions are L203.2 x W154.94 x H134.62 mm (L8.0 x W6.1 x H5.3 inches).
| Qty | Low | High |
|---|---|---|
| 1+ | $3.00 | $3.00 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The peak primary current is 10 A.
The turns ratio is 1:100 primary to secondary.
The secondary inductance is 2000 µH.
The operating frequency range is 50 kHz to 1000 kHz.
The operating temperature range is -40 °C to 125 °C.
The load resistance is 10 Ω.
Surface mount.