Have a small number of parts or want to add parts manually? Request Quote manually

Search across all market segments

CG0603MLC-3.3LE Bourns CG0603MLC-3.3LE is a single-channel ESD protector in a 0603 surface-mount package, offering 3.3V DC working voltage and ultra-low 0.2 pF typical capacitance.
Mfr Part #:

CG0603MLC-3.3LE

Available from 2 distributors
Mfr Name: Bourns
Bourns
Bourns CG0603MLC-3.3LE is a single-channel ESD protector in a 0603 surface-mount package, offering 3.3V DC working voltage and ultra-low 0.2 pF typical capacitance.
Total Stock: 8,084 pcs

CG0603MLC-3.3LE Available from 2 distributors

Authorised
Non-Authorised
Distributor Stock Pricing MOQ PKG Lead Time Date Code On Order Quantity On Order Delivery
Non-Authorised Inventory information
4,042 pcs
4042 pcs On Request 1 On Request On Request On Request On Request On Request
Non-Authorised Inventory information
4,042 pcs
4042 pcs On Request 1 On Request On Request On Request On Request On Request

CG0603MLC-3.3LE Specifications Quick View

Most important parameters for selection – full specs in datasheet.
Category
Manufacturer Name
AEC Qualified
AEC-Q200
Automotive Grade
Capacitance @ Frequency
Clamping Voltage (Typical)
DC Working Voltage
ESD Protection (Air Discharge)
ESD Protection (Contact Discharge)
ESD Withstand
Leakage Current
Maximum DC Volts
Mounting Type
Number of Circuits
Operating Temperature
Operating Temperature Range
Package / Case
Peak Voltage (Typical)
Prop 65
Response Time
Tape & Reel
Trigger Voltage (Typical)
capacitance (Typical/Nominal @ 1 MHz, 1 Vrms)

CG0603MLC-3.3LE Description

Short technical summary and product information.

The Bourns CG0603MLC-3.3LE is a monolithic ESD protection device from the ChipGuard MLC series, designed to safeguard sensitive electronics from electrostatic discharge events. It is housed in a compact 0603 (1608 metric) surface-mount package and uses multilayer ceramic varistor (MLCV) technology. The part provides bidirectional ESD clamping with a typical response time of less than 1 nanosecond.

 

Key electrical characteristics include a maximum DC working voltage of 3.3 V, very low leakage current below 0.01 µA, and an extremely low typical capacitance of 0.2 pF at 1 MHz, making it suitable for high-speed signal lines such as USB 3.0, camera links, and antenna ports. The device meets IEC 61000-4-2 Level 4 ESD requirements with ±8 kV contact and ±15 kV air discharge withstand, and it can endure 1000 typical ESD pulses (8 kV contact) without failure.

 

The operating temperature range is specified as -40 °C to +85 °C (per existing database) while the series datasheet indicates -55 °C to +125 °C. The part is listed as AEC-Q200 compliant and is marked with a California Proposition 65 warning. Available packaging options include tape and reel, cut tape, and Digi-Reel through distribution.

CG0603MLC-3.3LE Quick Information

Product Type: ESD Protection Device
Series: CGA0603MLC / CG0603MLC Series
Canonical Name: Bourns CG0603MLC-3.3LE ChipGuard MLC Series ESD Protector
Subcategory: Multilayer Ceramic Varistor (MLCV)

CG0603MLC-3.3LE Compliance

RoHS Status: RoHS Compliant
Moisture Sensitivity Level (MSL): 1 Unlimited
REACH Status: REACH Unaffected

CG0603MLC-3.3LE Features

  • Ultra-low capacitance of 0.2 pF typical.
  • <1 nanosecond response time to ESD.
  • ±8 kV contact and ±15 kV air discharge protection.
  • Bidirectional single-channel ESD suppressor.
  • Surface-mount 0603 (1608 metric) package.

CG0603MLC-3.3LE Applications

  • Protect high-speed USB 3.0 data lines.
  • Suitable for camera link interfaces.
  • Guard touchscreen controller inputs.
  • Used in GPS and antenna circuits.

CG0603MLC-3.3LE FAQs

4 frequently asked questions generated from this part’s specifications.
What is the maximum DC working voltage of the CG0603MLC-3.3LE?

The maximum DC working voltage is 3.3 V.

What is the typical capacitance of this ESD protector?

The typical capacitance is 0.2 pF at 1 MHz and 1 Vrms.

What ESD protection levels does the CG0603MLC-3.3LE provide?

It provides ±8 kV contact discharge and ±15 kV air discharge per IEC 61000-4-2 Level 4.

What is the operating temperature range?

The existing database lists -40°C to +85°C; the series datasheet indicates -55°C to +125°C. The correct range for this part needs verification.