CBW58-HS-5A-5C The OptiFuse CBW58-HS-5A-5C is a thermal circuit breaker rated for 5A at 250VAC/50VDC. It features a push-to-reset actuator and panel mount design.
Mfr Part #:

CBW58-HS-5A-5C

Mfr Name: OptiFuse
OptiFuse
The OptiFuse CBW58-HS-5A-5C is a thermal circuit breaker rated for 5A at 250VAC/50VDC. It features a push-to-reset actuator and panel mount design.
Stock on Request

CBW58-HS-5A-5C Specifications Quick View

Most important parameters for selection – full specs in datasheet.
Category
Manufacturer Name
Actuator Type
Approval Agency
Breaker Type
Current Rating (Amps)
Frequency
Illumination
Input Voltage
Insulation Resistance
Mounting Type
Number of Poles
Reset Time
Voltage Rating

CBW58-HS-5A-5C Description

Short technical summary and product information.

The OptiFuse CBW58-HS-5A-5C is a thermal circuit breaker designed for reliable overcurrent protection. It offers a current rating of 5A and can handle input voltages up to 250 VAC or 50 VDC, operating within a frequency range of 50-60 Hz.

 

This circuit breaker features a push-to-reset actuator for manual operation and a standard profile. It is designed for panel mounting, making it suitable for integration into various electrical enclosures and systems. The device has a dielectric strength of 1500 VAC for 1 minute and an insulation resistance greater than 100M Ω at 500 VDC.

 

Key specifications include an interrupting rating of 1000A at 125/250VAC and 300A at 50 VDC. The operating ambient temperature range is from -10℃ to +60℃. The breaker is also marine ignition protected to SAE J1171 and UL1500 standards. Agency listings include CCC, CSA, cURus, TUV, UR, and VDE.

CBW58-HS-5A-5C Quick Information

Product Type: Thermal Circuit Breaker
Series: CBW58
Canonical Name: OptiFuse CBW58-HS-5A-5C Thermal Circuit Breaker
Subcategory: Thermal

CBW58-HS-5A-5C Compliance

RoHS Status: RoHS Compliant
Moisture Sensitivity Level (MSL): 1 Unlimited
REACH Status: REACH Unaffected

CBW58-HS-5A-5C Features

  • Thermal circuit breaker with 5A rating.
  • Supports 250VAC and 50VDC operation.
  • Manual push-to-reset actuator.
  • Designed for panel mounting.
  • Marine ignition protected.

CBW58-HS-5A-5C Applications

  • Provides overcurrent protection.
  • Suitable for marine applications.
  • Used in panel-mounted systems.
  • General purpose circuit protection.

CBW58-HS-5A-5C FAQs

7 frequently asked questions generated from this part’s specifications.
What is the operating voltage of the CBW58-HS-5A-5C?

250VAC and 50VDC.

What is the operating temperature range?

-10°C to +60°C.

What is the interrupting rating?

1000A at 125/250VAC and 300A at 50VDC.

What is the dielectric strength?

1500VAC for 1 minute.

What is the reset time?

60 seconds.

What approvals does it have?

CCC, CSA, cURus, TUV, UR, VDE.

Is it marine ignition protected?

Yes, per SAE J1171 and UL1500.