Ready to onboard?
Are you ready to join DistyParts and
grow your business?
| Distributor | Stock | Pricing | MOQ | PKG | Lead Time | Date Code | On Order Quantity | On Order Delivery | |
|---|---|---|---|---|---|---|---|---|---|
|
48 pcs
|
48 pcs | On Request | 1 | On Request | On Request | On Request | On Request | On Request | |
|
48 pcs
|
48 pcs | On Request | 1 | On Request | On Request | On Request | On Request | On Request |
| Category | |
| Manufacturer Name | |
| AC Discharge Current (Nominal @ 50 Hz, 0.18 s (9 cycles), 1 operation) | |
| AC Discharge Current (Nominal @ 50 Hz, 1 s, 10 operations) | |
| Arc Voltage | |
| Capacitance | |
| Climatic Category | |
| DC Spark Over Voltage (Minimum/Nominal/Maximum) | |
| Fail Short | |
| Glow Voltage | |
| Glow to Arc Transition Current | |
| Impulse Discharge Current (8 | |
| Impulse Discharge Current (Nominal @ 10/1000 µs, 300 operations) | |
| Impulse Discharge Current (Nominal @ 10/350 µs, 1 operation) | |
| Impulse Discharge Current (Nominal @ 8/20 µs, 1 operation) | |
| Impulse Spark Over Voltage (Maximum @ 1 kV/µs, 99% of measured values) | |
| Impulse Spark Over Voltage (Maximum @ 100 V/µs, 99% of measured values) | |
| Impulse Spark Over Voltage (Typical @ 1 kV/µs, typical values of distribution) | |
| Impulse Spark Over Voltage (Typical @ 100 V/µs, typical values of distribution) | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Operating Temperature Range | |
| Tape & Reel | |
| Tolerance | |
| UL | |
| Voltage | |
| Weight |
The TDK B88069X5010C102 is a 2-electrode gas discharge tube (GDT) from the M51-C90X series, designed for overvoltage protection in telecom and data line applications. It features a nominal DC spark-over voltage of 90V with ±20% tolerance, and a minimum of 72V and maximum of 108V. The impulse spark-over voltage is less than 400V at 100V/µs (99% of measured values) and less than 600V at 1kV/µs. The GDT can handle impulse discharge currents up to 10kA (8/20µs, 1 operation) and 5kA (8/20µs, 10 operations). It also withstands AC discharge currents of 5A for 1 second (10 operations) and 10A for 0.18 seconds (1 operation). The device offers high insulation resistance (>1 GΩ at 50VDC) and low capacitance (<1 pF at 1MHz). It is packaged in an axial cylinder through-hole form, weighing approximately 1 gram. The operating temperature range is -40°C to +90°C, with a climatic category of 40/090/21 per IEC 60068-1. The GDT is RoHS-compatible and UL 497B certified (E163070).
| Qty | Low | High |
|---|---|---|
| 1+ | $2.26 | $2.26 |
| 10+ | $2.02 | $2.02 |
| 50+ | $1.68 | $1.68 |
| 100+ | $1.50 | $1.50 |
| 200+ | $1.38 | $1.38 |
| 500+ | $1.26 | $1.26 |
| 1,000+ | $1.20 | $1.20 |
| 5,000+ | $1.07 | $1.07 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The nominal DC spark-over voltage is 90V with ±20% tolerance, minimum 72V, maximum 108V.
Through Hole, Axial Cylinder package.
-40°C to +90°C.
Yes, it is RoHS-compatible per the datasheet and UL 497B certified.
5kA for 10 operations (8/20µs) and 10kA for 1 operation (8/20µs).
Less than 1 pF at 1 MHz.