The Altran Magnetics AMI-21-3-1 is a single phase EMI power line filter from the AMI-21 series. It is designed for general purpose conducted attenuation and features a single stage filter topology. The filter is rated for a maximum continuous operating voltage of 250VAC and a rated current of 3A.
Key electrical specifications include an inductance of 2.5 mH, line-to-line capacitance of 0.1 µF, and line-to-ground capacitance of 9.4 nF. Typical leakage current is 0.74 mA at 250VAC/50Hz and 0.43 mA at 120VAC/60Hz. The filter includes a 1000 kΩ discharge resistor and has a dielectric strength of 3000 VDC line-to-ground and 1100 VDC line-to-line.
The filter is designed for chassis mounting with quick connect termination style. It operates over a temperature range of -25°C to 100°C and an operating frequency range from DC to 400Hz. The AMI-21-3-1 carries CE and cURus approvals.
The rated voltage is 250VAC.
The rated current is 3 A.
The operating temperature range is -25°C to 100°C.
This filter uses chassis mount.
Typical leakage current is 0.74 mA at 250VAC/50Hz and 0.43 mA at 120VAC/60Hz.
It has CE and cURus approvals.
The filter is a single stage configuration.