The XP Power AFM60US24C2 is a versatile 60W AC/DC desktop power adapter designed for a wide range of applications, including IT equipment and medical devices. It operates with an input voltage range of 80-264 VAC and provides a stable 24V output.
This adapter features Level V energy efficiency, ensuring reduced power consumption. It boasts robust electrical specifications including ±1.0% line regulation and 2.5% load regulation, with a transient response of 4% max deviation. Safety is paramount, with isolation ratings of 4000 VAC input to output and 1500 VAC input to ground, along with comprehensive Overvoltage, Overload, and Short Circuit protections.
Designed for international use, the AFM60US24C2 includes an IEC 320-C8 polarized input connector and a barrel plug output connector (2.5mm I.D. x 5.5mm O.D.). Its compact desktop form factor measures 125.0mm x 62.0mm x 34.0mm, making it suitable for integration into various systems. The operating temperature range is from 0°C to 60°C, with derating above 40°C.
Compliance with international standards is a key feature, including CEC2008, EISA2007, EN55011/32/FCC Class B emissions, and various safety approvals such as IEC62368-1, IEC60601-1, UL60950-1, and UL60601-1. It also holds China Compulsory Certification (CCC) qualification.
The output voltage is 24V.
The maximum output power is 60W.
The input voltage range is 80-264 VAC.
It uses an IEC 320-C8 polarized input connector.
The operating temperature range is 0°C to 60°C.
Yes, it meets Level V energy efficiency.
It holds approvals including IEC62368-1, IEC60601-1, UL60950-1, and UL60601-1.