| Distributor | Stock | Pricing | MOQ | PKG | Lead Time | Date Code | On Order Quantity | On Order Delivery | |
|---|---|---|---|---|---|---|---|---|---|
|
9 pcs
|
9 pcs | On Request | 1 | On Request | On Request | 1970-01-01 00:33:29 | On Request | On Request |
| Category | |
| Manufacturer Name | |
| Automotive Grade | |
| Body Length | |
| Capacitance | |
| Climate Category | |
| DC Resistance | |
| Dielectric Strength | |
| Industrial Grade | |
| Insertion Loss (Typical @ 10 MHz) | |
| Insertion Loss (Typical @ 100 MHz) | |
| Insertion Loss (Typical @ 30 MHz) | |
| Insertion Loss (Typical @ 400 MHz) | |
| Lead Style | |
| Medical Grade | |
| Military Grade | |
| Mounting Type | |
| Operating Temperature (Minimum/Maximum) | |
| Overall Length | |
| Package Style | |
| Pulse Capability | |
| Rated Current | |
| Rated Frequency | |
| Rated Temperature | |
| Rated Voltage (DC) | |
| Rated Voltage AC | |
| Termination Style | |
| Thread Size |
The KEMET AFCL060115NJT1T is a small signal feed-through filter from the AFCL 060 series, designed for applications requiring good temperature stability and fast transient handling. It uses film capacitor technology with self-healing properties and is housed in a robust, sealed threaded metal case with tag terminations.
Key electrical specifications include a capacitance of 1500 pF, rated voltage of 630 VDC / 125 VAC, rated current of 10 A at 400 Hz, and a maximum DC resistance of 6 mΩ. The filter offers a pulse capability of 2000 V/µs and typical insertion loss of 8 dB at 10 MHz, 18 dB at 30 MHz, 27 dB at 100 MHz, and 43 dB at 400 MHz.
The operating temperature range is -55°C to +125°C with a climate category of 55/125/56. The package style is AFCL 060 with a 5/16-24 UNF thread size, maximum body length 6.1 mm, and overall length 8 mm. This product is RoHS compliant.
The capacitance is 1500 pF.
Rated voltage is 630 VDC and 125 VAC.
The operating temperature range is -55°C to +125°C.
It uses a threaded metal case package style AFCL 060 with tag terminations and 5/16-24 UNF thread size.
Yes, the datasheet states that KEMET EMI filters are RoHS compliant.
Typical insertion loss at 100 MHz is 27 dB.