The XP Power AEM60US15 is a versatile 60 Watt AC/DC desktop adapter designed for international use. It delivers a stable 15V output at 4A, suitable for various applications including medical equipment due to its worldwide medical approvals and 4000 VAC isolation.
This adapter features high efficiency of 85% and operates across a wide input voltage range of 80-264 VAC. Key electrical specifications include ±1% line regulation and ±6% load regulation, with protections for overload and short circuits. The device is convection-cooled and designed for reliability with a typical MTBF of 300 kHrs.
Mechanically, the AEM60US15 has a compact desktop form factor (Class II construction) with dimensions of 132.1mm x 58.0mm x 30.5mm. It utilizes an IEC 320-C8 input connector and a standard barrel plug output connector (2.5mm I.D. x 5.5mm O.D. x 12.0mm) with positive center polarization. The operating temperature range is 0°C to 60°C, with derating at higher temperatures.
Compliance includes CE and UKCA markings, along with adherence to standards such as EN55011 Level B for emissions and various EN61000 immunity standards. It is also RoHS3 compliant.
The input voltage range is 80-264 VAC.
The operating temperature range is 0°C to +60°C, with derating above +40°C.
The output voltage is 15V and the output current is 4A.
It is approved to UL60601-1, EN60601-1, IEC60601-1, CE and UKCA.
The efficiency is 85%.
The isolation voltage is 4000 VAC input to output.
It uses a barrel plug with 2.5mm ID x 5.5mm OD, positive center.