The ADG508FBRNZ is a CMOS analog multiplexer from Analog Devices that provides fault protection for both the device and signal source. It comprises eight single channels with an 8:1 configuration. The multiplexer can withstand continuous overvoltage inputs from -40V to +55V, and during power loss, the input appears as an open circuit with only nanoamperes of leakage current.
Key electrical characteristics include a typical on-resistance of 270Ohm, maximum switch on time of 230ns, and off time of 130ns. Charge injection is 15pC typical, and off leakage current is 1nA typical. The device operates from a nominal ±15V supply and is TTL and CMOS compatible. It features break-before-make switching construction and latch-up proof design.
The ADG508FBRNZ is housed in a 16-SOIC surface-mount package (0.154", 3.90mm width) and operates over a temperature range of -40°C to +85°C. Power dissipation is 3.3mW maximum. This multiplexer is suitable for both existing fault-protected and non-fault-protected applications, as well as new designs requiring multiplexer functions.
The typical on-resistance is 270Ohm.
The nominal supply voltage is ±15V.
The operating temperature range is -40°C to +85°C.
It is available in a 16-SOIC surface-mount package (0.154", 3.90mm width).
The part is marked as RoHS3 compliant, but this is unverified.
Maximum turn-on time is 230ns, maximum turn-off time is 130ns.
Yes, it provides fault protection for continuous overvoltage inputs from -40V to +55V.