| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Features | |
| Height | |
| Input Frequency | |
| Input Voltage | |
| Length | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Output Voltage | |
| Power (Watts) | |
| SVHC Present | |
| Standard Number | |
| Type | |
| Voltage | |
| Width |
The Cosel ADA600F-36-W is a high-performance AC/DC power supply unit designed for various industrial applications. This enclosed converter offers a stable 36V DC output with a nominal current of 10A, delivering up to 360W of power under convection cooling, and can reach 594W with forced air.
Key electrical specifications include a universal input voltage range of AC85-264V and a power factor of 0.98-0.99 typical. It boasts high efficiency, reaching up to 89% at AC200V input. The unit incorporates features such as overcurrent protection, overvoltage protection, and harmonic attenuation compliant with IEC61000-3-2.
Designed for reliability, the ADA600F-36-W operates within an ambient temperature range of -10°C to 71°C with derating. Its robust construction and chassis mount type make it suitable for integration into various systems. Safety approvals include CE, CSA, cURus, TUV, and UL, adhering to standards like IEC60950-1 and IEC62368-1. EMI compliance is met with FCC-B, CISPR22-B, EN55022-B, and VCCI-B standards.
The input voltage range is 85-264VAC at 50/60Hz, with a DC input option of 120-350VDC.
The output voltage is 36V nominal, adjustable from 33.0-41.0V. Output current is 9A (convection) or 14A (forced air) at 100VAC input, and 10A (convection) or 16.5A (forced air) at 200VAC input.
The operating temperature range is -10°C to 71°C with derating.
It includes overcurrent protection (activates above 101% of peak current with automatic recovery) and overvoltage protection set at 41-60V.
It measures 195mm x 127mm x 65mm and is designed for chassis mount in an enclosed package.
Typical efficiency is 86% at 100VAC input and 89% at 200VAC input, both at full load.
It complies with UL60950-1, C-UL(CSA60950-1), EN62368-1 safety standards, and EMI standards FCC-B, CISPR22-B, EN55022-B, VCCI-B.