| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Features | |
| Height | |
| Input Frequency | |
| Input Voltage | |
| Length | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Output Voltage | |
| Power (Watts) | |
| Standard Number | |
| Type | |
| Voltage | |
| Width |
The Cosel ADA600F-30-W is an enclosed AC/DC power supply designed for ITE (Commercial) applications. It offers a nominal output voltage of 30V and a current rating of 12A under convection cooling, with a peak current capability of 24.5A. Under forced air cooling, the current increases to 20A with a peak of 24.5A. The unit operates with universal input voltage from AC85-264V and features Power Factor Correction (PFC), achieving typical efficiencies of 86% at 100V input and 87% at 200V input.
Key electrical specifications include a line regulation of 120mV maximum and a load regulation of 180mV maximum. The ripple and noise are kept within limits, with a maximum ripple of 160mVp-p at 0 to +50°C. The power supply has a start-up time of 500ms maximum and a hold-up time of 20ms typical. It includes overcurrent and overvoltage protection circuits.
Mechanically, the ADA600F-30-W is a chassis mount unit with dimensions of 195.0mm x 127.0mm x 65.0mm. It operates within a temperature range of -10°C to 71°C with derating. Safety agency approvals include CE, CSA, cURus, TUV, and UL, complying with standards like UL60950-1 and EN62368-1. The product also complies with EMI standards such as FCC-B and CISPR22-B, and harmonic attenuation requirements per IEC61000-3-2.
The input voltage range is 85-264V AC, or 120-350V DC.
The nominal output voltage is 30V, adjustable from 27.0V to 33.0V.
The operating temperature range is -10°C to 71°C with derating.
Dimensions are 195mm (L) x 127mm (W) x 65mm (H).
It is certified to UL60950-1, C-UL(CSA60950-1), and EN62368-1.
Efficiency is typically 86% at 100V AC input and 87% at 200V AC input, at full load.
Yes, overcurrent protection works above 101% of peak current and recovers automatically.