| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Features | |
| Height | |
| Input Frequency | |
| Input Voltage | |
| Length | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Output Voltage | |
| Power (Watts) | |
| SVHC Present | |
| Standard Number | |
| Type | |
| Voltage | |
| Width |
The Cosel ADA1000F-24-FR is an enclosed AC/DC converter designed for ITE (Commercial) applications. It provides a stable 24V output voltage and can deliver up to 600W of power under convection cooling, or 1008W with forced air.
Key electrical specifications include a universal input voltage range of AC85 - 264V and an efficiency of 88% typical. The converter features Power Factor Correction (PFC) and meets harmonic attenuation standards compliant with IEC61000-3-2. It offers features such as adjustable output, DC input capability, standby output, and remote ON/OFF functionality.
Designed for robust performance, it operates within a temperature range of -10°C to 71°C with derating. The unit is chassis mounted and has dimensions of 280.0mm x 127.0mm x 75.0mm. Safety agency approvals include CE, CSA, cURus, TUV, and UL, with standard compliance to 60950-1 and 62368-1.
This model includes overcurrent and overvoltage protection circuits for enhanced reliability. It is suitable for various industrial and commercial applications requiring a dependable power supply.
The input voltage range is 85-264 VAC.
The operating temperature range is -10°C to 71°C with derating.
The output voltage is 24V. Output current depends on cooling: convection 14A (peak 25A) at 100VAC, 15A (peak 31A) at 200VAC; forced air 21A (peak 25A) at 100VAC, 25A (peak 31A) at 200VAC.
Overcurrent protection works above 101% of peak current and recovers automatically. Overvoltage protection is set at 31-34.5V.
Dimensions are 280.0mm x 127.0mm x 75.0mm. Mounting type is chassis mount.
The isolation voltage is 3kV.