| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Features | |
| Height | |
| Industrial Grade | |
| Input Frequency | |
| Input Voltage | |
| Length | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power (Watts) | |
| Standard Number | |
| Type | |
| Voltage | |
| Width |
The Cosel ADA1000F-24-E is an enclosed AC/DC converter designed for ITE (Commercial) applications. It provides a 24V output voltage and a power rating of 600W under convection cooling, with a higher rating of 1008W available with forced air.
This converter features a universal input voltage range of AC85 - 264V and supports a 50/60Hz input frequency. Key electrical specifications include an output current of up to 25A (peak) at ACIN 200V with forced air, line regulation of 96mV maximum, and load regulation of 150mV maximum. It also includes overcurrent and overvoltage protection circuits.
Designed for reliable operation, the ADA1000F-24-E has an operating temperature range of -10°C to 71°C (with derating). Its dimensions are 280.0mm x 127.0mm x 75.0mm, and it is suitable for chassis mounting.
The unit complies with various safety and EMI standards, including UL60950-1, C-UL(CSA60950-1), EN62368-1, FCC-B, CISPR22-B, EN55022-B, and VCCI-B. It also features harmonic attenuation compliant with IEC61000-3-2 and EMS compliance according to EN61204-3 and EN61000-6-2.
85-264 VAC.
Nominal 24V, adjustable 21.6-27V. Current ratings depend on input and cooling: 14A (100V convection) to 25A (200V forced air), with peak currents up to 31A.
84% typical at 100V input, 86% typical at 200V input (full load).
Yes, overcurrent protection works above 101% of peak current and recovers automatically. Overvoltage protection is set at 31-34.5V.
-10°C to +71°C with derating.
Enclosed chassis mount.
UL60950-1, C-UL (CSA60950-1), EN62368-1, CE, CSA, cURus, TUV, UL. Also complies with DEN-AN and EMI standards FCC-B, CISPR22-B, EN55022-B, VCCI-B.