AD5274BCPZ-100-RL7 AD5274BCPZ-100-RL7 is a 256-position digital rheostat from Analog Devices with 100 kOhms resistance and I2C interface. It features non-volatile memory and operates from 2.7V to 5.5V single supply.
Mfr Part #:

AD5274BCPZ-100-RL7

Available from 1 distributors
Mfr Name: Analog Devices / Maxim Integrated
Analog Devices / Maxim Integrated
AD5274BCPZ-100-RL7 is a 256-position digital rheostat from Analog Devices with 100 kOhms resistance and I2C interface. It features non-volatile memory and operates from 2.7V to 5.5V single supply.
Total Stock: 1,155 pcs

AD5274BCPZ-100-RL7 Available from 1 distributor

Authorised
Non-Authorised
Distributor Stock Pricing MOQ PKG Lead Time Date Code On Order Quantity On Order Delivery
Non-Authorised Inventory information
1,155 pcs
1155 pcs On Request 1 On Request On Request 22+ On Request On Request

AD5274BCPZ-100-RL7 Specifications Quick View

Most important parameters for selection – full specs in datasheet.
Category
Manufacturer Name
Configuration
Features
Interface
Memory Type
Mounting Type
Number of Circuits
Number of Taps
Operating Temperature
Resistance
Resistance (Ohms)
SVHC Present
Supplier Device Package
Tape & Reel
Taper
Temperature Coefficient
Temperature Coefficient (Typ)
Tolerance
Voltage

AD5274BCPZ-100-RL7 Description

Short technical summary and product information.

Analog Devices AD5274BCPZ-100-RL7 is a single-channel, 256-position digital rheostat belonging to the AD5272/AD5274 family. It offers a nominal resistance of 100 kOhms with a maximum ±1% end-to-end tolerance error and a typical temperature coefficient of 5 ppm/°C. The device is controlled via an I2C-compatible interface and incorporates 50-times programmable (50-TP) non-volatile memory to store wiper positions.

 

The rheostat operates from a single supply of 2.7 V to 5.5 V or a dual supply of ±2.5 V to ±2.75 V, making it suitable for both DC and AC/bipolar applications. The operating temperature range is -40°C to +125°C. The selectable address feature allows multiple devices to share the same I2C bus.

 

The AD5274 simplifies precision calibration and open-loop applications due to its low resistor tolerance error. Typical applications include replacing mechanical rheostats, variable gain control in op-amp circuits, instrumentation gain and offset adjustment, programmable filters, and sensor calibration.

 

The device is supplied in a surface-mount 10-lead LFCSP package measuring 3 mm × 3 mm with an exposed pad (10-LFCSP-WD). Based on available data, the moisture sensitivity level is MSL 1 (unlimited), but this information is unverified.

AD5274BCPZ-100-RL7 Quick Information

Product Type: Digital Rheostat
Series: AD5274
Canonical Name: AD5274BCPZ-100-RL7
Subcategory: Digital Potentiometers

AD5274BCPZ-100-RL7 Compliance

RoHS Status: RoHS Compliant
Moisture Sensitivity Level (MSL): 1 Unlimited
REACH Status: REACH Unaffected
Lead Free: Yes

AD5274BCPZ-100-RL7 Features

  • 256-position resolution with linear taper.
  • 100 kOhms nominal resistance with ±1% tolerance.
  • I2C-compatible interface with selectable address.
  • Non-volatile 50-times programmable wiper memory.
  • Operates from 2.7V to 5.5V single supply.

AD5274BCPZ-100-RL7 Applications

  • Replaces mechanical rheostats in precision circuits.
  • Variable gain control in operational amplifier circuits.
  • Instrumentation gain and offset calibration.
  • Programmable filters, delays, and time constants.
  • Sensor calibration and adjustment applications.

AD5274BCPZ-100-RL7 FAQs

7 frequently asked questions generated from this part’s specifications.
What is the operating voltage range for the AD5274BCPZ-100-RL7?

The device operates from a single supply of 2.7V to 5.5V or a dual supply of ±2.5V to ±2.75V.

What package does the AD5274BCPZ-100-RL7 come in?

It comes in a 10-lead LFCSP package with exposed pad, measuring 3mm x 3mm (10-LFCSP-WD).

What is the operating temperature range?

The operating temperature range is -40°C to +125°C.

Is the AD5274BCPZ-100-RL7 RoHS compliant?

Based on available data, the component is marked as RoHS3 Compliant, but this information is unverified and should be confirmed with the manufacturer.

How many tap positions does the digital rheostat have?

The AD5274BCPZ-100-RL7 has 256 tap positions.

What interface is used to control the device?

The device uses an I2C-compatible interface with a selectable address.

Does the device retain its wiper setting after power-off?

Yes, the wiper setting is stored in non-volatile memory with 50-times programmable capability.