This OptiFuse ACBP-N-10C is a single-pole circuit breaker rated for 10 Amperes and 32 Volts DC. It features an automatic reset mechanism, allowing it to restore power after tripping due to overcurrent conditions.
The circuit breaker is constructed with a thermoplastic body (UL94V-0 rated) and copper-plated battery terminals with zinc-plated auxiliary terminals. It is designed for chassis mounting and meets SAE J1171 for ignition protection and IP63 for ingress protection.
Key specifications include an interrupting rating of 4 times the rated current and an operating temperature range of -10°C to 60°C. Testing is performed according to SAE J553 standards. The studs have a torque rating of 3.0±0.3 N.m.
This component is suitable for applications requiring reliable overcurrent protection in environments where ignition protection and dust/water resistance are important.
32 VDC.
10A.
-10°C to 60°C.
Yes, it is an auto reset circuit breaker.
4 times rated current (40A).
Chassis mount.
SAE J553, SAE J1171, and IP63.