Ready to onboard?
Are you ready to join DistyParts and
grow your business?
| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Features | |
| Frequency | |
| Height | |
| Hold Up Time | |
| Humidity | |
| Isolation (@ Input/output) | |
| Leakage Current | |
| Length | |
| Line Regulation | |
| Load Regulation | |
| MTBF | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Output Voltage | |
| Over Current Protection | |
| Over Temperature Protection | |
| Over Voltage Protection | |
| Power (Watts) | |
| Power Factor | |
| Remote Sensing | |
| Ripple & Noise | |
| Short circuit protection | |
| Standard Number | |
| Storage Temperature | |
| Temperature Coefficient | |
| Trim | |
| Type | |
| Vibration | |
| Voltage | |
| Voltage Accuracy | |
| Weight | |
| Width |
The ARCH ABR300-24S is an enclosed AC/DC converter designed for ITE (Commercial) applications. It delivers a maximum output wattage of 300W with a nominal output voltage of 24V and a maximum output current of 12.5A.
This converter operates with a universal input voltage range of 90-264 VAC and supports a frequency of 50/60 Hz. Key electrical specifications include high efficiency up to 90.5%, power factor greater than 0.9, and tight voltage accuracy of ±2%. Protection features include over-current, over-voltage, over-temperature, and short-circuit protection with auto-recovery.
The unit is designed for through-hole mounting and has a full brick form factor with a baseplate for conduction cooling. Its physical dimensions are 117.2mm x 61.4mm x 13.2mm. The operating temperature range is -40°C to 100°C, and it boasts an MTBF of over 250,000 hours at 25°C.
The input voltage range is 90 to 264 VAC at 50/60 Hz.
It uses an 11-DIP module package with through-hole mounting.
The operating temperature range is -40°C to 100°C when mounted on an aluminum base plate.
Output voltage is 24V DC with a maximum current of 12.5A, providing 300W total power.
Over current, over voltage, and over temperature protections are auto recovery. Short circuit protection is auto recovery with hiccup mode.
Length 117.2mm, width 61.4mm, height 13.2mm. Weight 111g.
Efficiency is 90.5% at full load.