| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Breaker Type | |
| Illumination | |
| Mounting Type | |
| Number of Poles | |
| Voltage Rating |
The E-T-A 9510-G213-J1F1-B2R2B9 is a single-pole magnetic circuit breaker designed for reliable circuit protection. It features a push-pull actuation mechanism and precise trip characteristics, making it suitable for applications requiring accurate current interruption.
This circuit breaker is available with voltage ratings of 24 VDC and 28 VDC, with corresponding trip currents of less than 170 mA and 200 mA, respectively. The trip time is consistently under 25 ms for both ratings. It operates within a temperature range of -30 °C to 60 °C and offers high insulation resistance.
The 9510-G213-J1F1-B2R2B9 supports various mounting methods, including threadneck and flange mounting, and offers different terminal configurations such as screw terminals, blade terminals, and wire wrap terminals. It can be optionally equipped with an auxiliary contact for signaling purposes.
Typical applications include flight simulators, where precise and reliable circuit interruption is critical. The magnetic operation ensures a consistent trip behavior across different conditions.
The circuit breaker is rated for 28VDC operation with a trip current of 200mA, and also supports 24VDC operation with a trip current of 170mA.
It is panel mounted with a threadneck design available in M12x1x6.3 or 7/16-32UNx6.3. Terminal configurations include screw terminals, blade terminals, or wire wrap terminals.
The operating temperature range is -30°C to 60°C.
The maximum trip current is 200mA at 28VDC and 170mA at 24VDC, with a trip time under 25ms.
Yes, it includes an auxiliary contact rated for 28VDC at 0.5A resistive load or 0.2A lamp load.
Typical life is 10,000 operations without auxiliary contact and 5,000 operations with auxiliary contact at rated voltage.
It uses an internal logic diode circuit (R2 configuration).