| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Mounting Type | |
| Number of Poles | |
| Operating Temperature | |
| Storage Temperature | |
| Tape & Reel | |
| Voltage Rating |
This E-T-A 8340-T120-K1T2-ALH126-12A is a magnetic and hydraulic-magnetic circuit breaker designed for reliable overcurrent protection. It features a 12A current rating and is suitable for AC voltages up to 240/415VAC and DC voltages up to 80VDC.
With a 2-pole configuration and a toggle actuator, this circuit breaker offers enhanced reliability and precision. It is approved by CSA, GB, IEC, and UL standards, ensuring compliance for various applications. The breaker type is magnetic with hydraulic delay, providing robust protection against overloads.
The unit is designed for DIN rail mounting, making it easy to integrate into electrical panels and systems. It operates within an ambient temperature range of -40 to 85°C and offers an interrupting capacity of 3,500A at 250VAC and 80VDC.
Typical applications include power supplies, control equipment, communication systems, and EDP systems. Its durable construction and adherence to safety standards make it a dependable choice for industrial and automotive systems requiring precise power management and distribution solutions.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The current rating is 12A.
It is rated for 240/415VAC and 80VDC.
This circuit breaker has 2 poles.
It is designed for DIN rail mounting.
The ambient temperature range is -40 to 85°C.
The interrupting capacity is 3,500A at 250VAC and 3,500A at 80VDC.