| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Ambient Temperature | |
| Approval Agency | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Mounting Type | |
| Number of Poles | |
| Voltage Rating |
This E-T-A 8340-T120-K1T1-ALH0-15A is a robust 2-pole magnetic and hydraulic-magnetic circuit breaker designed for reliable overcurrent protection.
It features a 15A current rating and can operate at up to 240VAC or 80VDC. The breaker utilizes a toggle actuator and is designed for DIN rail mounting, ensuring easy integration into standard electrical enclosures.
Approved by CSA, GB, IEC, and UL standards, this circuit breaker is suitable for various applications requiring dependable circuit protection. Its hydraulic delay characteristic helps prevent nuisance tripping from temporary inrush currents while still providing protection against sustained overloads.
Typical applications include power supplies, control equipment, communication systems, and EDP systems. The breaker operates within an ambient temperature range of -40°C to 85°C.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The current rating is 15A.
It supports 240VAC and 80VDC.
This circuit breaker has 2 poles.
It is designed for DIN rail mounting.
The operating temperature range is -40°C to 85°C.
It is approved by CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, and UL489A.