| Distributor | Stock | Pricing | MOQ | PKG | Lead Time | Date Code | On Order Quantity | On Order Delivery | |
|---|---|---|---|---|---|---|---|---|---|
|
900 pcs
|
900 pcs | On Request | 1 | On Request | On Request | On Request | On Request | On Request |
| Category | |
| Manufacturer Name | |
| Approval Agency | |
| Breaking Capacity (Maximum @ 400 VDC) | |
| Breaking Capacity (Maximum @ 500 VAC) | |
| Breaking Capacity @ Rated Voltage | |
| Climatic Category | |
| Current Rating | |
| Current Rating (Amps) | |
| Diameter | |
| Fuse Type | |
| Industrial Grade | |
| Length | |
| Material - Endcaps | |
| Material - Leads | |
| Material Tube | |
| Melting I²t | |
| Mounting Type | |
| Operating Temperature | |
| Package Type | |
| Response Time | |
| Size | |
| Storage Temperature | |
| Termination Style | |
| Unit Weight | |
| Voltage Rating | |
| Voltage Rating AC | |
| Voltage Rating DC |
The Schurter 8020.5014.G is a 6.3x32 mm cartridge fuse from the SHT series, rated at 2A with a voltage rating of 500VAC and 400VDC. It features a time-lag T (slow blow) characteristic, making it suitable for applications with pulse-shaped continuous currents. The fuse has a high breaking capacity of 3.5kA at 500VAC and 1.5kA at 400VDC.
The fuse is constructed with a ceramic tube and nickel-plated copper alloy endcaps, with tin-plated copper axial leads. It operates over a temperature range of -40°C to 85°C and is classified under climatic category 40/085/21 per IEC 60068-1. The unit weight is 2.84 g.
This fuse is designed for primary protection in 3-phase applications, DC applications, photovoltaic systems, frequency converters, power electronics, and commercial cooking appliances per UL 197. It requires a fuse holder or clip for mounting and is cURus approved under UL 248-14 and CSA22.2 No. 248.14.
| Qty | Low | High |
|---|---|---|
| 1+ | $1.28 | $1.28 |
| 10+ | $1.18 | $1.18 |
| 50+ | $0.86 | $0.86 |
| 100+ | $0.79 | $0.79 |
| 250+ | $0.73 | $0.73 |
| 500+ | $0.68 | $0.68 |
| 1,000+ | $0.63 | $0.63 |
| 2,000+ | $0.60 | $0.60 |
| 5,000+ | $0.54 | $0.54 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The current rating is 2 A.
The voltage rating is 500 VAC and 400 VDC.
The breaking capacity is 3.5 kA at 500 VAC and 1.5 kA at 400 VDC.
The fuse has a slow blow (time-lag T) response.
The package is 3AB, 3AG, 1/4" x 1-1/4" (6.35 mm diameter x 31.8 mm length).
It is cURus approved under UL 248-14 and CSA22.2 No. 248.14.
The operating temperature range is -40°C to 85°C.