The 78M6610+PSU is an energy metering integrated circuit from Analog Devices, designed for high-accuracy power monitoring in AC/DC power supplies. It supports precision measurements of better than 1% accuracy, making it suitable for applications requiring detailed power analysis.
The device operates with a single 3.3 VDC supply. The datasheet indicates that resistive current shunts and voltage dividers are commonly used for sensor connections, and the device is typically powered through an auxiliary winding of the SMPS transformer. The recommended sensor location is behind the EMI filtering circuit for a balanced approach to component and calibration costs.
This IC is part of the Analog Devices portfolio, known for its power management solutions. Its design guidelines focus on integrating precise power monitoring capabilities into various power supply designs, offering flexibility in sensor placement and communication methods like UART for data isolation.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.75 | $0.75 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The 78M6610+PSU requires a 3.3 VDC supply voltage.
The RoHS status is RoHS3 Compliant.
The Moisture Sensitivity Level is 1 Unlimited.
The REACH status is REACH Unaffected.