The 71M6103-ILR/F is an integrated circuit designed for 3-phase energy metering applications. Manufactured by Analog Devices Inc. (formerly Maxim Integrated), this IC offers precise measurement capabilities with a low error rate of 0.1%.
It operates over an industrial temperature range of -40°C to 85°C and requires a supply voltage between 2.5V and 3.6V. The device is housed in an 8-SOIC package, suitable for surface mounting.
This energy meter IC is designed to work with non-isolating sensors like resistive shunts, reducing Bill of Materials (BOM) costs by eliminating the need for costly isolation transformers or CTs. It provides galvanic isolation through a pulse transformer, enabling a bidirectional digital communication link. The IC includes a 22-bit delta-sigma ADC, an amplifier, a precision voltage reference, and a temperature sensor.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.75 | $0.75 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The supply voltage range is 2.5V to 3.6V.
The device is available in an 8-SOIC package (0.154 inch width, 3.90mm body width).
The operating temperature range is -40°C to 85°C.
The typical supply current is 770µA.
The measurement error is 0.1%.
Yes, it is a 3 phase meter type.