| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Operating Temperature | |
| Storage Temperature | |
| Tape & Reel | |
| Voltage Rating |
This E-T-A 482 series thermal circuit breaker, part number 482-G212-K1M1-A1S0-1.5A, is a single-pole device designed for high-performance protection in various applications. It offers a current rating of 1.5A and can handle voltages up to 230V AC or 28V DC.
The breaker utilizes a thermal trip mechanism with a snap-action, tease-free, and trip-free design, ensuring reliable operation. Manual actuation is achieved via a push/pull plunger, and an indicator band clearly shows the tripped or off position. The unit is designed for threadneck panel mounting.
Key technical specifications include an interrupting capacity of up to 6,000A DC / 1,000A AC for higher current ratings, and it operates within an ambient temperature range of -55°C to +75°C. The device meets various approval standards including CSA C22.2 No 235, IEC 60934, and UL1077, making it suitable for demanding environments such as tracked vehicles and aircraft.
Environmental and mechanical robustness are supported by features like IP40 protection for the operating area, resistance to vibration, shock, corrosion, and humidity, adhering to relevant VG and IEC standards. The compact design and reliable thermal protection make it a suitable choice for extra-low voltage wiring systems on vehicles, battery-powered machines, and process control applications.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The current rating is 1.5A.
It is rated for 230V AC and 28V DC.
It is designed for threadneck panel mounting.
The ambient temperature range is -55°C to +75°C.
It uses a push-pull plunger for manual actuation.